The constant temperature and humidity laboratory produced by Dongguan Haotian Testing Equipment Co., Ltd. has three major brands: Comtek compressor, German Copeland compressor and German BITZER compressor. The working principle of the compressor: The walk-in constant temperature and humidity laboratory compressor is a driven fluid machine that raises low pressure gas to high pressure. It is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it by running the motor, and then discharges high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle. Refrigeration cycle of compression → condensation → expansion → evaporation (endothermic). What should we check if there is a leak? The refrigeration system of the walk-in constant temperature and humidity test chamber is used for leak detection. The leak detector and the soapy water are combined to check where the leak is. If it is found that the stem of the hot gas bypass solenoid valve is cracked, there is a slit. Then replace the solenoid valve. If it finds a leak in other places, repair the leak at the leak with oxygen welding, and then refill the system with fluorine, and the system will return to normal. Optical Rotary Sensor,Custom Encoder,Optical Encoder 6Mm Shaft,Handwheel Pulse Generator Jilin Lander Intelligent Technology Co., Ltd , https://www.jllandertech.com